Recently, we received serval report back that the Ubox V2 is easy to throw out the abs cover current fault with FW 5.3, after researches and experiments, we have found that we can do these configurations to improve the robustness to the abs fault.
Prepares
For hard ware modification:
Ubox V2 with panel removed, a suitable inner hexagon spanner is needed.
A knife to scrape the coating of the PCB.
An iron and solder wire.
For FW configuration:
The VESC tool, we use VESC tool 3.01 PC edition in this guide.