Difference between revisions of "E-fuse beta1 manual"
From Spintend service and support
(Created page with "E-fuse is to provide a electronic power switch with overcurrent protection and anti-sparking function. The physical fuse is simple and reliable, but reacts too slow. For example, out 120A fuse, when current is 240A, it will take 1 minute to blow, this is some times too late. = Feature = * Aluminum power stage PCB with stacked logic stage. * 120A max current, 15A, 30A, 60A, 120A, 240A, 300A configurable, beyond 120A is only for temporary test. * 80V max battery volt...") |
|||
Line 1: | Line 1: | ||
E-fuse is to provide a electronic power switch with overcurrent protection and anti-sparking function. | E-fuse is to provide a electronic power switch with overcurrent protection and anti-sparking function. | ||
The physical fuse is simple and reliable, but reacts too slow. For example, out 120A fuse, when current is 240A, it will take 1 minute to blow, this is some times too late. | The physical fuse is simple and reliable, but reacts too slow. For example, out 120A fuse, when current is 240A, it will take 1 minute to blow, this is some times too late. And they are lack of flexibility. | ||
= Feature = | = Feature = |
Revision as of 21:41, 25 December 2022
E-fuse is to provide a electronic power switch with overcurrent protection and anti-sparking function.
The physical fuse is simple and reliable, but reacts too slow. For example, out 120A fuse, when current is 240A, it will take 1 minute to blow, this is some times too late. And they are lack of flexibility.
Feature
- Aluminum power stage PCB with stacked logic stage.
- 120A max current, 15A, 30A, 60A, 120A, 240A, 300A configurable, beyond 120A is only for temporary test.
- 80V max battery voltage, 100V can be achieve by change the MOSFET.
- Anti-spark.
- Power switch, support momentary/latching button, ignite key.
- Slide to power on, can be set off by a switch.
- Auto power off after 20 minutes, when ESC is idle, also can be set off by a switch.
- Size: